CGM sensor
A compact BLE transmitter that wirelessly relays glucose data from the CGM sensor to smartphones, dedicated receivers, or cloud platforms. Supports multi-device pairing for caregiver sharing.
Specifications
| Connectivity | Bluetooth 5.0 BLE |
| Range | 10m / 33ft |
| Multi-device | Up to 5 paired devices |
| Battery Life | 90 days (replaceable) |
| Dimensions | 20 x 20 x 6 mm |
| Weight | 4.0 g |
| Compatibility | iOS 14+ / Android 8+ |
| Data Protocol | GATT Profile |
Features
- Multi-device pairing for caregiver sharing
- Ultra-low power consumption
- Replaceable battery (90-day life)
- Secure encrypted data transmission
- Cloud data sync capability
Applications
Enzymatic Technology & Clinical Validation
Enzymatic Sensing Technology
Our CGM sensors utilize third-generation enzymatic electrochemical technology with glucose oxidase (GOx) immobilized on a platinum electrode surface. The enzymatic reaction converts glucose concentration into measurable electrical current with high specificity and minimal interference from ascorbic acid, uric acid, and acetaminophen.
- •Enzyme: Glucose Oxidase (GOx) from Aspergillus niger, purity ≥95%
- •Electrode: Platinum working electrode with Ag/AgCl reference
- •Interference Rejection: <5% signal deviation at physiological levels of interfering substances
- •Calibration: Factory-calibrated using ISO 15197:2013 reference method
Clinical Accuracy Validation
Accuracy validated through multi-center clinical trials following ISO 15197:2013 and CLSI POCT12-A3 guidelines. Over 500 sensor-wear days across 120 subjects with type 1 and type 2 diabetes.
Industry benchmark: 11-12%
FDA requirement: ≥95%
Clinical acceptability threshold: 95%
Technical Documentation
Manufacturing Process
Cleanroom assembly (ISO Class 7), automated enzyme deposition with ±2% precision, 100% in-line electrical testing, and accelerated aging validation (40°C/75% RH for 6 months).
Quality Control
Four-stage inspection: IQC (incoming materials), IPQC (in-process), FQC (final), OQC (outgoing). Statistical process control with Cpk ≥1.33 for critical parameters.
Regulatory Compliance
Design history file (DHF) maintained per 21 CFR 820.30. Validation protocols per ISO 14971 risk management. Biocompatibility testing per ISO 10993-5 and ISO 10993-10.
Technical Review by GlucoTech R&D Team
Reviewed by Dr. Sarah Chen, Ph.D. in Biomedical Engineering, 15+ years in biosensor development. Last updated: January 2026. For technical inquiries, contact our engineering team at tech@cgm-manufacture.com.
Customization Options
- Custom Firmware
- Custom Protocol Integration
- Custom Logo
Packaging & Shipping
Individual box with battery. Export carton: 150 units.