CGM
CGM manufacturer - CGM sensor

CGM sensor

A compact BLE transmitter that wirelessly relays glucose data from the CGM sensor to smartphones, dedicated receivers, or cloud platforms. Supports multi-device pairing for caregiver sharing.

CEFCCRoHSISO 13485

Specifications

ConnectivityBluetooth 5.0 BLE
Range10m / 33ft
Multi-deviceUp to 5 paired devices
Battery Life90 days (replaceable)
Dimensions20 x 20 x 6 mm
Weight4.0 g
CompatibilityiOS 14+ / Android 8+
Data ProtocolGATT Profile

Features

  • Multi-device pairing for caregiver sharing
  • Ultra-low power consumption
  • Replaceable battery (90-day life)
  • Secure encrypted data transmission
  • Cloud data sync capability

Applications

Remote Patient MonitoringCaregiver AlertsTelemedicine IntegrationClinical Data Collection

Enzymatic Technology & Clinical Validation

Enzymatic Sensing Technology

Our CGM sensors utilize third-generation enzymatic electrochemical technology with glucose oxidase (GOx) immobilized on a platinum electrode surface. The enzymatic reaction converts glucose concentration into measurable electrical current with high specificity and minimal interference from ascorbic acid, uric acid, and acetaminophen.

  • •Enzyme: Glucose Oxidase (GOx) from Aspergillus niger, purity ≥95%
  • •Electrode: Platinum working electrode with Ag/AgCl reference
  • •Interference Rejection: <5% signal deviation at physiological levels of interfering substances
  • •Calibration: Factory-calibrated using ISO 15197:2013 reference method

Clinical Accuracy Validation

Accuracy validated through multi-center clinical trials following ISO 15197:2013 and CLSI POCT12-A3 guidelines. Over 500 sensor-wear days across 120 subjects with type 1 and type 2 diabetes.

MARD (Mean Absolute Relative Difference)<9%

Industry benchmark: 11-12%

Clarke Error Grid Zone A+B96.8%

FDA requirement: ≥95%

Consensus Error Grid Zone A+B98.2%

Clinical acceptability threshold: 95%

Technical Documentation

Manufacturing Process

Cleanroom assembly (ISO Class 7), automated enzyme deposition with ±2% precision, 100% in-line electrical testing, and accelerated aging validation (40°C/75% RH for 6 months).

Quality Control

Four-stage inspection: IQC (incoming materials), IPQC (in-process), FQC (final), OQC (outgoing). Statistical process control with Cpk ≥1.33 for critical parameters.

Regulatory Compliance

Design history file (DHF) maintained per 21 CFR 820.30. Validation protocols per ISO 14971 risk management. Biocompatibility testing per ISO 10993-5 and ISO 10993-10.

Technical Review by GlucoTech R&D Team

Reviewed by Dr. Sarah Chen, Ph.D. in Biomedical Engineering, 15+ years in biosensor development. Last updated: January 2026. For technical inquiries, contact our engineering team at tech@cgm-manufacture.com.

Customization Options

  • Custom Firmware
  • Custom Protocol Integration
  • Custom Logo

Packaging & Shipping

Individual box with battery. Export carton: 150 units.

Sea FreightAir FreightExpress