CGM Sensor Lite 15-Day
A compact and affordable CGM solution designed for short-term glucose monitoring, screening programs, and patients preferring shorter wear cycles. Maintains high accuracy with simplified application.
Specifications
| Wear Duration | 7 days |
| Reading Interval | 60 seconds |
| Accuracy (MARD) | < 10% |
| Glucose Range | 40-400 mg/dL (2.2-22.2 mmol/L) |
| Water Resistance | IP27 |
| Operating Temperature | 10-45°C / 50-113°F |
| Dimensions | 22 x 22 x 4.0 mm |
| Weight | 3.0 g |
| Connectivity | Bluetooth 5.0 BLE |
| Battery | Integrated, 7-day life |
Features
- Compact and lightweight design
- Easy one-step applicator
- Real-time glucose data with trends
- Smartphone app compatibility
- Affordable for screening programs
Applications
Enzymatic Technology & Clinical Validation
Enzymatic Sensing Technology
Our CGM sensors utilize third-generation enzymatic electrochemical technology with glucose oxidase (GOx) immobilized on a platinum electrode surface. The enzymatic reaction converts glucose concentration into measurable electrical current with high specificity and minimal interference from ascorbic acid, uric acid, and acetaminophen.
- •Enzyme: Glucose Oxidase (GOx) from Aspergillus niger, purity ≥95%
- •Electrode: Platinum working electrode with Ag/AgCl reference
- •Interference Rejection: <5% signal deviation at physiological levels of interfering substances
- •Calibration: Factory-calibrated using ISO 15197:2013 reference method
Clinical Accuracy Validation
Accuracy validated through multi-center clinical trials following ISO 15197:2013 and CLSI POCT12-A3 guidelines. Over 500 sensor-wear days across 120 subjects with type 1 and type 2 diabetes.
Industry benchmark: 11-12%
FDA requirement: ≥95%
Clinical acceptability threshold: 95%
Technical Documentation
Manufacturing Process
Cleanroom assembly (ISO Class 7), automated enzyme deposition with ±2% precision, 100% in-line electrical testing, and accelerated aging validation (40°C/75% RH for 6 months).
Quality Control
Four-stage inspection: IQC (incoming materials), IPQC (in-process), FQC (final), OQC (outgoing). Statistical process control with Cpk ≥1.33 for critical parameters.
Regulatory Compliance
Design history file (DHF) maintained per 21 CFR 820.30. Validation protocols per ISO 14971 risk management. Biocompatibility testing per ISO 10993-5 and ISO 10993-10.
Technical Review by GlucoTech R&D Team
Reviewed by Dr. Sarah Chen, Ph.D. in Biomedical Engineering, 15+ years in biosensor development. Last updated: January 2026. For technical inquiries, contact our engineering team at tech@cgm-manufacture.com.
Customization Options
- Custom Logo Printing
- Custom Packaging
- Custom App Branding
Packaging & Shipping
Individual blister pack. Export carton: 200 units.