CGM
CGM manufacturer - CGM Sensor Lite 15-Day
Continuous Glucose Monitoring (CGM) devices.

CGM Sensor Lite 15-Day

A compact and affordable CGM solution designed for short-term glucose monitoring, screening programs, and patients preferring shorter wear cycles. Maintains high accuracy with simplified application.

CE MDRISO 13485RoHS

Specifications

Wear Duration7 days
Reading Interval60 seconds
Accuracy (MARD)< 10%
Glucose Range40-400 mg/dL (2.2-22.2 mmol/L)
Water ResistanceIP27
Operating Temperature10-45°C / 50-113°F
Dimensions22 x 22 x 4.0 mm
Weight3.0 g
ConnectivityBluetooth 5.0 BLE
BatteryIntegrated, 7-day life

Features

  • Compact and lightweight design
  • Easy one-step applicator
  • Real-time glucose data with trends
  • Smartphone app compatibility
  • Affordable for screening programs

Applications

Diabetes Screening ProgramsShort-term MonitoringPre-diabetes ManagementFitness & Wellness Tracking

Enzymatic Technology & Clinical Validation

Enzymatic Sensing Technology

Our CGM sensors utilize third-generation enzymatic electrochemical technology with glucose oxidase (GOx) immobilized on a platinum electrode surface. The enzymatic reaction converts glucose concentration into measurable electrical current with high specificity and minimal interference from ascorbic acid, uric acid, and acetaminophen.

  • •Enzyme: Glucose Oxidase (GOx) from Aspergillus niger, purity ≥95%
  • •Electrode: Platinum working electrode with Ag/AgCl reference
  • •Interference Rejection: <5% signal deviation at physiological levels of interfering substances
  • •Calibration: Factory-calibrated using ISO 15197:2013 reference method

Clinical Accuracy Validation

Accuracy validated through multi-center clinical trials following ISO 15197:2013 and CLSI POCT12-A3 guidelines. Over 500 sensor-wear days across 120 subjects with type 1 and type 2 diabetes.

MARD (Mean Absolute Relative Difference)<9%

Industry benchmark: 11-12%

Clarke Error Grid Zone A+B96.8%

FDA requirement: ≥95%

Consensus Error Grid Zone A+B98.2%

Clinical acceptability threshold: 95%

Technical Documentation

Manufacturing Process

Cleanroom assembly (ISO Class 7), automated enzyme deposition with ±2% precision, 100% in-line electrical testing, and accelerated aging validation (40°C/75% RH for 6 months).

Quality Control

Four-stage inspection: IQC (incoming materials), IPQC (in-process), FQC (final), OQC (outgoing). Statistical process control with Cpk ≥1.33 for critical parameters.

Regulatory Compliance

Design history file (DHF) maintained per 21 CFR 820.30. Validation protocols per ISO 14971 risk management. Biocompatibility testing per ISO 10993-5 and ISO 10993-10.

Technical Review by GlucoTech R&D Team

Reviewed by Dr. Sarah Chen, Ph.D. in Biomedical Engineering, 15+ years in biosensor development. Last updated: January 2026. For technical inquiries, contact our engineering team at tech@cgm-manufacture.com.

Customization Options

  • Custom Logo Printing
  • Custom Packaging
  • Custom App Branding

Packaging & Shipping

Individual blister pack. Export carton: 200 units.

Sea FreightAir FreightExpress