CGM Sensor Pro 14-Day

Our flagship CGM sensor delivers laboratory-grade glucose monitoring in a comfortable, water-resistant wearable patch. Factory-calibrated for no-fingerstick convenience, it provides real-time glucose readings every 60 seconds with trend arrows and customizable alerts.

CE MDRFDA 510(k)ISO 13485RoHS

Specifications

Wear Duration14 days
Reading Interval60 seconds
Accuracy (MARD)< 9%
Glucose Range40-400 mg/dL (2.2-22.2 mmol/L)
Water ResistanceIP28 (2.4m depth, 24 hours)
Operating Temperature10-45°C / 50-113°F
Dimensions24 x 24 x 4.5 mm
Weight3.5 g
ConnectivityBluetooth 5.0 BLE
BatteryIntegrated, 14-day life

Features

  • Factory-calibrated, no fingerstick required
  • Real-time glucose readings with trend arrows
  • Customizable high/low glucose alerts
  • Water-resistant for swimming and showering
  • Compatible with iOS and Android apps
  • Data export for healthcare provider review

Applications

Type 1 Diabetes ManagementType 2 Diabetes MonitoringHospital & Clinical UseHome Care & Remote MonitoringClinical Trials & Research

Enzymatic Technology & Clinical Validation

Enzymatic Sensing Technology

Our CGM sensors utilize third-generation enzymatic electrochemical technology with glucose oxidase (GOx) immobilized on a platinum electrode surface. The enzymatic reaction converts glucose concentration into measurable electrical current with high specificity and minimal interference from ascorbic acid, uric acid, and acetaminophen.

  • •Enzyme: Glucose Oxidase (GOx) from Aspergillus niger, purity ≥95%
  • •Electrode: Platinum working electrode with Ag/AgCl reference
  • •Interference Rejection: <5% signal deviation at physiological levels of interfering substances
  • •Calibration: Factory-calibrated using ISO 15197:2013 reference method

Clinical Accuracy Validation

Accuracy validated through multi-center clinical trials following ISO 15197:2013 and CLSI POCT12-A3 guidelines. Over 500 sensor-wear days across 120 subjects with type 1 and type 2 diabetes.

MARD (Mean Absolute Relative Difference)<9%

Industry benchmark: 11-12%

Clarke Error Grid Zone A+B96.8%

FDA requirement: ≥95%

Consensus Error Grid Zone A+B98.2%

Clinical acceptability threshold: 95%

Technical Documentation

Manufacturing Process

Cleanroom assembly (ISO Class 7), automated enzyme deposition with ±2% precision, 100% in-line electrical testing, and accelerated aging validation (40°C/75% RH for 6 months).

Quality Control

Four-stage inspection: IQC (incoming materials), IPQC (in-process), FQC (final), OQC (outgoing). Statistical process control with Cpk ≥1.33 for critical parameters.

Regulatory Compliance

Design history file (DHF) maintained per 21 CFR 820.30. Validation protocols per ISO 14971 risk management. Biocompatibility testing per ISO 10993-5 and ISO 10993-10.

Technical Review by GlucoTech R&D Team

Reviewed by Dr. Sarah Chen, Ph.D. in Biomedical Engineering, 15+ years in biosensor development. Last updated: January 2026. For technical inquiries, contact our engineering team at tech@cgm-manufacture.com.

Customization Options

  • Custom Logo Printing
  • Custom Packaging Design
  • Custom App Branding (White Label)
  • Custom Alert Thresholds
  • Custom Firmware Configuration

Packaging & Shipping

Individual blister pack, 1 sensor per box. Export carton: 100 units. Custom packaging available.

Sea FreightAir FreightExpress